DIGITAL DATA LOGGER
GS-DDL-06

Introduction

The digital data logger is an advanced instrument designed for the precise measurement and monitoring of environmental data, including groundwater levels and subsurface water pressure changes. This device provides essential data for environmental monitoring and hydrological studies, ensuring accurate and reliable information on water table fluctuations.


DIGITAL-DATA-LOGGER
DIGITAL-DATA-LOGGER3
DIGITAL-DATA-LOGGER2
DIGITAL-DATA-LOGGER3
DIGITAL-DATA-LOGGER
Features

1. Ultra-low power consumption: 20µA in sleep mode

2. Delayed data collection for power supply: filters and reports data only after removing anomalies

3. Online monitoring: Data application on PC and mobile devices, real-time/historical/alarm data query

4. Remote configuration: Collection frequency, sending frequency, alarm upper and lower limits can be configured

5. User-friendly data collection and configuration: compatible with all products meeting the standard MODBUS-RTU protocol.

6. Enhanced EMC interference resistance: monitored by hardware and software, suitable for harsh industrial environments with severe electromagnetic interference

7. 24/7 online monitoring: data server records data for several years

8. API interface of an open cloud platform: seamless integration with user-specific platforms

Specification

Model

GS-DDL-06

Power Supply Types

Solar Powered

External Power Supply

Input Signal

RS485MODBUS-RTUinterface, supports up to 64 devices (standard MODBUS-RTU protocol)

Supply Voltage

Built-in 7800mAH lithium battery, integrated solar panel charging (can also be externally powered with 3.7~5V)

10~30VDC

Output Voltage

12VDC (300mA), short supply in sleep mode, powers downlink sensors only when collecting data, no power supply to sensors during sleep mode

Synchronized with external power, short supply in sleep mode, powers downlink sensors only when collecting data, no power supply to sensors during sleep mode

SIM Card

Built-in

Protocol

MODBUS-TCP

Network

4G/GSM

Antenna

Built-in (optional)

Sampling Interval

 Freely configurable in seconds

Upload Interval

Freely configurable in minutes, minimum 1 minute

Wake-up Mode

Scheduled and alarm wake-up

Configuration Mode

configuration/remote configuration (remote configuration requires commands from platform)

Upload Information

Data from each collection point, battery information, network status, signal strength, alarm information, etc.

Power Consumption

Standby current ≤ 20µA

Average emission current ≤ 100mA

Operating Temperature

-20℃ to 70℃

Storage Temperature

-40℃ to 85℃

Protection Level

IP67/IP65